Local and currently valid legislation must be observed. It is mainspowered and must be protected against accidental contact Locate the ignition electrode and the ionization probe such that the ignition spark cannot arc over to the ionization probe (risk of electrical overloads) Commissioning notes Prior to commissioning, check to ensure that wiring is in an orderly state and that the parameters have been correctly set 2/32ģ Standards and certificates Conformity to EEC directives - Electromagnetic compatibility EMC (immunity) - Directive for gas appliances - Low-voltage directive 89 / 336 EEC 90 / 396 EEC 73 / 23 EEC ISO 9001: 2000 Cert ISO 14001: 1996 Cert LMV51.000B1 x LMV51.000B2 x x x x LMV51.040B x x x x LMV51.100B1 x LMV51.100B2 x x x x LMV51.140B x x x x LMV51.200A1 x LMV51.200A2 x x - x LMV52.200A1 x LMV52.200A2 x x - x LMV52.240A x x x x LMV52.240A Service notes Each time a unit has been replaced, check to ensure that wiring is in an orderly state If fuses are blown, the unit must be returned to Siemens Disposal notes The unit contains electrical and electronic components and must not be disposed of together with domestic waste. Such units must not be put into operation, even if they do not exhibit any damage Mounting notes Ensure that the relevant national safety regulations are complied with Installation notes Always run high-voltage ignition cables separately while observing the greatest possible distance to the unit and to other cables Do not mix up live and neutral conductors Electrical connection of the flame detectors It is important to achieve practically disturbance- and loss-free signal transmission: Never run the detector cable together with other cables Line capacitance reduces the magnitude of the flame signal Use a separate cable Observe the maximum permissible detector cable lengths The ionization probe is not protected against electric shock hazard. Siemens will not assume responsibility for any damage resulting from unauthorized interference! All activities (mounting, installation and service work, etc.) must be performed by qualified staff Before making any wiring changes in the connection area of the LMV5., completely isolate the unit from the mains supply (all-polar disconnection) Ensure protection against electric shock hazard by providing adequate protection for the burner control s connection terminals Check to ensure that wiring is in an orderly state Fall or shock can adversely affect the safety functions. is a safety device! Do not open, interfere with or modify the unit. system (P7550)! To avoid injury to persons, damage to property or the environment, the following warning notes should be observed! The LMV5. burner management system is a microprocessor-based unit with matching system components for the control and supervision of forced draft burners of medium to high capacity HVAC ProductsĢ Warning notes For additional safety notes, refer to the Basic Documentation of the LMV5. and this Data Sheet are intended for use by OEMs which integrate the burner management systems in their products! Use The LMV5.

free iso burner hardware error 14849

Burner control with integrated fuel / air ratio control and load control for forced draft burners including oxygen trim control. Burner control with integrated fuel / air ratio control and load control for forced draft burners.










Free iso burner hardware error 14849